ABUS Security-Center AZ4000 Alarm

RS noliktavas nr.: 704-4041Ražotājs: ABUS Security-CenterRažotāja kods: AZ4000
brand-logo
View all in Signalizācijas

Tehniskie dokumenti

Specifikācija

Number of Wired Zones

8

Maximum Number of User Codes

16

Supply Voltage

230V

Depth

85 mm

Height

235 mm

Width

235mm

Izcelsmes valsts

China

Produkta apraksts

Terxon SX Alarm Panel

The Terxon SX alarm panel is an entry level alarm center for smaller properties. 9 zones ensure gap-free security. The system has 8 freely programmable zones for wired detectors. Zone 9 is the sabotage zone. Only NC detectors can be connected. The type of wiring is left up to you (NC or DEOL sabotage contact in series or as its own zone). The signal generator has its own (reserved) sabotage zone on the motherboard. Three 500mA transistor switching outputs that can be assigned to a certain event (alarm, fire or robbery) are located on the motherboard. the Terxon SX can also be expanded with a relay board (8 x 1A relays).,Supplied with a white LCD control unit, which allows the system to be quickly and conveniently programmed or activated/deactivated. You can connect 3 additional control units. The connection is made via 4-wire bus wiring.,16 users with their own codes and chip keys can operate the system.

Noliktavas stāvoklis patreiz nav pieejams

Lūdzu pārbaudiet vēlreiz vēlāk

Noliktavas stāvoklis patreiz nav pieejams

€ 308,00

Katrs (bez PVN)

€ 372,68

Katrs (Ieskaitot PVN)

ABUS Security-Center AZ4000 Alarm

€ 308,00

Katrs (bez PVN)

€ 372,68

Katrs (Ieskaitot PVN)

ABUS Security-Center AZ4000 Alarm
Noliktavas stāvoklis patreiz nav pieejams

Tehniskie dokumenti

Specifikācija

Number of Wired Zones

8

Maximum Number of User Codes

16

Supply Voltage

230V

Depth

85 mm

Height

235 mm

Width

235mm

Izcelsmes valsts

China

Produkta apraksts

Terxon SX Alarm Panel

The Terxon SX alarm panel is an entry level alarm center for smaller properties. 9 zones ensure gap-free security. The system has 8 freely programmable zones for wired detectors. Zone 9 is the sabotage zone. Only NC detectors can be connected. The type of wiring is left up to you (NC or DEOL sabotage contact in series or as its own zone). The signal generator has its own (reserved) sabotage zone on the motherboard. Three 500mA transistor switching outputs that can be assigned to a certain event (alarm, fire or robbery) are located on the motherboard. the Terxon SX can also be expanded with a relay board (8 x 1A relays).,Supplied with a white LCD control unit, which allows the system to be quickly and conveniently programmed or activated/deactivated. You can connect 3 additional control units. The connection is made via 4-wire bus wiring.,16 users with their own codes and chip keys can operate the system.