Schneider Electric 3 Phase Surge Protector, 40kA

RS noliktavas nr.: 815-3278Ražotājs: Schneider ElectricRažotāja kods: SDSA3650
brand-logo
View all in Surge Protection Devices

Tehniskie dokumenti

Specifikācija

Device Type

Surge Arrestor

Maximum Surge Current

40kA

Electrical Phase

3

Impulse Discharge Current

10kA

Length

92mm

Width

76mm

Depth

67mm

Dimensions

92 x 76 x 67mm

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

+65°C

Operating Temperature Range

-40 → +65 °C

Izcelsmes valsts

United States

Produkta apraksts

Surge Protection

Square D

For use with Qwikline I consumer units and can be retrofitted in to existing systems,Type B characteristic offers instantaneous short circuit response level of 3-5 x normal rated current, making it suitable for circuits with moderate inrush currents such as filament lamps, heating loads and most domestic/small building protection applications.,Type C characteristic offers short circuit response of 5-10 x normal rated current, making it ideal for circuits with higher inrush currents such as motor control and fluorescent lighting installations in industrial buildings where nuisance tripping might occur if a faster type was used

Noliktavas stāvoklis patreiz nav pieejams

Lūdzu pārbaudiet vēlreiz vēlāk

Noliktavas stāvoklis patreiz nav pieejams

€ 520,00

Katrs (bez PVN)

€ 629,20

Katrs (Ieskaitot PVN)

Schneider Electric 3 Phase Surge Protector, 40kA

€ 520,00

Katrs (bez PVN)

€ 629,20

Katrs (Ieskaitot PVN)

Schneider Electric 3 Phase Surge Protector, 40kA
Noliktavas stāvoklis patreiz nav pieejams

Tehniskie dokumenti

Specifikācija

Device Type

Surge Arrestor

Maximum Surge Current

40kA

Electrical Phase

3

Impulse Discharge Current

10kA

Length

92mm

Width

76mm

Depth

67mm

Dimensions

92 x 76 x 67mm

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

+65°C

Operating Temperature Range

-40 → +65 °C

Izcelsmes valsts

United States

Produkta apraksts

Surge Protection

Square D

For use with Qwikline I consumer units and can be retrofitted in to existing systems,Type B characteristic offers instantaneous short circuit response level of 3-5 x normal rated current, making it suitable for circuits with moderate inrush currents such as filament lamps, heating loads and most domestic/small building protection applications.,Type C characteristic offers short circuit response of 5-10 x normal rated current, making it ideal for circuits with higher inrush currents such as motor control and fluorescent lighting installations in industrial buildings where nuisance tripping might occur if a faster type was used