RS PRO Signal Conditioner, Current, Voltage Input, Current, Voltage Output, 10 → 30V dc Supply

RS noliktavas nr.: 218-4469Ražotājs: RS PRO
brand-logo
View all in Signal Conditioners

Tehniskie dokumenti

Specifikācija

Brand

RS Pro

Module Type

Signal Isolator

Input Signal Type

Current, Voltage

Output Signal Type

Current, Voltage

Input Range

0 → 20 mA, -250 → +250V dc

Output Range

0 → 10 mA, 0 → 10V dc

Supply Voltage

10 → 30V dc

Mounting Type

DIN Rail Mount

Operating Temperature Range

0 → +50°C

Series

9100

Minimum Operating Temperature

0°C

Maximum Operating Temperature

+50°C

Termination

Screw

Izcelsmes valsts

United Kingdom

Produkta apraksts

24Vdc Trip Amplifiers, Signal Isolator/Converters

Symmetric DIN rail mounting units with finger protected terminals designed for use in process control and instrumentation applications. Single or dual level trip amplifiers from a single Input.Each trip can be arranged so that the alarm condition can be above (high trip) or below (low trip) the set point, and that the relay can be either normally energised to de-energise in the alarm condition (fail-safe), or normally de-energised to energise in the alarm condition (non fail-safe).,signal Isolators/converter; this unit conditions the signal before sending it through an opto-isolated hybrid circuit. Input and output stages are power from separate secondaries of the dc/dc inverter to provide 3 port isolation

Noliktavas stāvoklis patreiz nav pieejams

Lūdzu pārbaudiet vēlreiz vēlāk

Noliktavas stāvoklis patreiz nav pieejams

€ 250,00

Katrs (bez PVN)

€ 302,50

Katrs (Ieskaitot PVN)

RS PRO Signal Conditioner, Current, Voltage Input, Current, Voltage Output, 10 → 30V dc Supply

€ 250,00

Katrs (bez PVN)

€ 302,50

Katrs (Ieskaitot PVN)

RS PRO Signal Conditioner, Current, Voltage Input, Current, Voltage Output, 10 → 30V dc Supply
Noliktavas stāvoklis patreiz nav pieejams

Tehniskie dokumenti

Specifikācija

Brand

RS Pro

Module Type

Signal Isolator

Input Signal Type

Current, Voltage

Output Signal Type

Current, Voltage

Input Range

0 → 20 mA, -250 → +250V dc

Output Range

0 → 10 mA, 0 → 10V dc

Supply Voltage

10 → 30V dc

Mounting Type

DIN Rail Mount

Operating Temperature Range

0 → +50°C

Series

9100

Minimum Operating Temperature

0°C

Maximum Operating Temperature

+50°C

Termination

Screw

Izcelsmes valsts

United Kingdom

Produkta apraksts

24Vdc Trip Amplifiers, Signal Isolator/Converters

Symmetric DIN rail mounting units with finger protected terminals designed for use in process control and instrumentation applications. Single or dual level trip amplifiers from a single Input.Each trip can be arranged so that the alarm condition can be above (high trip) or below (low trip) the set point, and that the relay can be either normally energised to de-energise in the alarm condition (fail-safe), or normally de-energised to energise in the alarm condition (non fail-safe).,signal Isolators/converter; this unit conditions the signal before sending it through an opto-isolated hybrid circuit. Input and output stages are power from separate secondaries of the dc/dc inverter to provide 3 port isolation