Megger LTW425-EU-BS Loop Impedance & RCD Combined Tester, Loop Impedance Test Type 2 Wire 440V, RCD Test Type AC

RS noliktavas nr.: 198-441Ražotājs: MeggerRažotāja kods: LTW425-EU-BS
brand-logo
Skatīt visu Loop & RCD Testers

Tehniskie dokumenti

Specifikācija

Brand

Megger

Loop Impedance Test Type

2 Wire

Test Equipment Type

Combined Loop & RCD Tester

Maximum Voltage Measurement

440V

RCD Test Type

AC Selective

PSC Display

No

Best Loop Test Accuracy

±10%

RCD Test Current

4A

Non-Trip Loop Test

Yes

Safety Category

CAT IV 300 V, IEC 61010

Display Type

LCD

Battery Life

2000 tests

Battery Type

AA

Power Source

Battery

Dimensions

203 x 148 x 78mm

Weight

1000g

Width

148mm

Minimum Operating Temperature

-10°C

Height

78mm

Model Number p

LTW425

Safety Category Level

CAT IV

Safety Category Voltage

300V

Length

203mm

Maximum Operating Temperature

+50°C

Izcelsmes valsts

United Kingdom

Produkta apraksts

LTW425

The Megger LTW425 two wire earth loop tester verifies the loop impedance of a live electrical circuit, ie without the need to disconnect the electrical supply. Offers a high resolution 2-wire loop testing solution that does not trip 30 mA RCDs and can be used on a wide range of voltages.

Supplied with

Test lead set with crocodile clips, mains socket test lead, 8 AA alkaline batteries, hard carry case and instructions.

Noliktavas stāvoklis patreiz nav pieejams

Lūdzu pārbaudiet vēlreiz vēlāk

Noliktavas stāvoklis patreiz nav pieejams

€ 920,00

Katrs (bez PVN)

€ 1 113,20

Katrs (Ieskaitot PVN)

Megger LTW425-EU-BS Loop Impedance & RCD Combined Tester, Loop Impedance Test Type 2 Wire 440V, RCD Test Type AC

Kalibrācijas veids

€ 920,00

Katrs (bez PVN)

€ 1 113,20

Katrs (Ieskaitot PVN)

Megger LTW425-EU-BS Loop Impedance & RCD Combined Tester, Loop Impedance Test Type 2 Wire 440V, RCD Test Type AC
Noliktavas stāvoklis patreiz nav pieejams

Kalibrācijas veids

Tehniskie dokumenti

Specifikācija

Brand

Megger

Loop Impedance Test Type

2 Wire

Test Equipment Type

Combined Loop & RCD Tester

Maximum Voltage Measurement

440V

RCD Test Type

AC Selective

PSC Display

No

Best Loop Test Accuracy

±10%

RCD Test Current

4A

Non-Trip Loop Test

Yes

Safety Category

CAT IV 300 V, IEC 61010

Display Type

LCD

Battery Life

2000 tests

Battery Type

AA

Power Source

Battery

Dimensions

203 x 148 x 78mm

Weight

1000g

Width

148mm

Minimum Operating Temperature

-10°C

Height

78mm

Model Number p

LTW425

Safety Category Level

CAT IV

Safety Category Voltage

300V

Length

203mm

Maximum Operating Temperature

+50°C

Izcelsmes valsts

United Kingdom

Produkta apraksts

LTW425

The Megger LTW425 two wire earth loop tester verifies the loop impedance of a live electrical circuit, ie without the need to disconnect the electrical supply. Offers a high resolution 2-wire loop testing solution that does not trip 30 mA RCDs and can be used on a wide range of voltages.

Supplied with

Test lead set with crocodile clips, mains socket test lead, 8 AA alkaline batteries, hard carry case and instructions.