Dehn, DR Surge Protection Plug 255 V ac/dc Maximum Voltage Rating 5kA Maximum Surge Current Surge Arrester Protection

RS noliktavas nr.: 768-1808Ražotājs: DehnRažotāja kods: DR MOD 255
brand-logo

Tehniskie dokumenti

Specifikācija

Brand

Dehn

Suppressor Type

Surge Arrester Protection Module

Maximum Voltage Rating

255 V ac/dc

Mounting Type

Plug In

Maximum Surge Current

5kA

Series

DR

Length

45mm

Depth

18mm

Height

51mm

Dimensions

45 x 18 x 51mm

Izcelsmes valsts

Germany

Produkta apraksts

DEHNguard and DEHNrail Replacement Plugin Modules

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.

Noliktavas stāvoklis patreiz nav pieejams

Lūdzu pārbaudiet vēlreiz vēlāk

Noliktavas stāvoklis patreiz nav pieejams

€ 143,00

Katrs (bez PVN)

€ 173,03

Katrs (Ieskaitot PVN)

Dehn, DR Surge Protection Plug 255 V ac/dc Maximum Voltage Rating 5kA Maximum Surge Current Surge Arrester Protection

€ 143,00

Katrs (bez PVN)

€ 173,03

Katrs (Ieskaitot PVN)

Dehn, DR Surge Protection Plug 255 V ac/dc Maximum Voltage Rating 5kA Maximum Surge Current Surge Arrester Protection
Noliktavas stāvoklis patreiz nav pieejams

Pirkt iepakojumos

DaudzumsVienības cena
1 - 4€ 143,00
5 - 9€ 137,00
10 - 19€ 130,00
20 - 29€ 119,00
30+€ 106,00

Tehniskie dokumenti

Specifikācija

Brand

Dehn

Suppressor Type

Surge Arrester Protection Module

Maximum Voltage Rating

255 V ac/dc

Mounting Type

Plug In

Maximum Surge Current

5kA

Series

DR

Length

45mm

Depth

18mm

Height

51mm

Dimensions

45 x 18 x 51mm

Izcelsmes valsts

Germany

Produkta apraksts

DEHNguard and DEHNrail Replacement Plugin Modules

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.