Chauvin Arnoux E3N Current Clamp, 150A DC Max, AC/DC Adapter, 150A ac AC Max

RS noliktavas nr.: 212-039Ražotājs: Chauvin ArnouxRažotāja kods: P01120043A
brand-logo
View all in Current Clamps

Tehniskie dokumenti

Specifikācija

Adapter Type

AC/DC

Maximum DC Current

150A

Maximum ac Current

150A ac

Best Accuracy

±3%

Maximum Conductor Size

12mm

Safety Category

CAT IV 300 V, CAT III 600V

Connector Type

BNC to Banana Plug

Maximum Bandwidth

100kHz

Bandwidth

DC → 100kHz

Model Number p

E3N

Safety Category Level

CAT III, CAT IV

Safety Category Voltage

300 V, 600V

Izcelsmes valsts

France

Produkta apraksts

Chauvin Arnoux E3 AC/DC Probe

The E3N clamp has been designed to measure AC and DC currents by using Hall-effect technology. Due to its shape this clamp is ideal for measurements in cable bundles and confined spaces especially the wiring on switchboards.

Warning

Not to be used on conductors where the potential exceeds 650V r.m.s.

Noliktavas stāvoklis patreiz nav pieejams

Lūdzu pārbaudiet vēlreiz vēlāk

Noliktavas stāvoklis patreiz nav pieejams

€ 354,00

Katrs (bez PVN)

€ 428,34

Katrs (Ieskaitot PVN)

Chauvin Arnoux E3N Current Clamp, 150A DC Max, AC/DC Adapter, 150A ac AC Max

€ 354,00

Katrs (bez PVN)

€ 428,34

Katrs (Ieskaitot PVN)

Chauvin Arnoux E3N Current Clamp, 150A DC Max, AC/DC Adapter, 150A ac AC Max
Noliktavas stāvoklis patreiz nav pieejams

Tehniskie dokumenti

Specifikācija

Adapter Type

AC/DC

Maximum DC Current

150A

Maximum ac Current

150A ac

Best Accuracy

±3%

Maximum Conductor Size

12mm

Safety Category

CAT IV 300 V, CAT III 600V

Connector Type

BNC to Banana Plug

Maximum Bandwidth

100kHz

Bandwidth

DC → 100kHz

Model Number p

E3N

Safety Category Level

CAT III, CAT IV

Safety Category Voltage

300 V, 600V

Izcelsmes valsts

France

Produkta apraksts

Chauvin Arnoux E3 AC/DC Probe

The E3N clamp has been designed to measure AC and DC currents by using Hall-effect technology. Due to its shape this clamp is ideal for measurements in cable bundles and confined spaces especially the wiring on switchboards.

Warning

Not to be used on conductors where the potential exceeds 650V r.m.s.