Carlo Gavazzi Soft Starter, Soft Start, 5.5 kW, 400 V ac, 3 Phase, IP20

RS noliktavas nr.: 785-0767Ražotājs: Carlo GavazziRažotāja kods: RSGD4025F0VD20
brand-logo
View all in Motor Starters

Tehniskie dokumenti

Specifikācija

Power Rating

5.5 kW

Motor Starter Type

Soft Start

Voltage Rating

400 V ac

Phase

3

Current Rating

25 A

IP Rating

IP20

Overall Length

125mm

Overall Width

45mm

Overall Depth

109.8mm

Series

RSGD

Izcelsmes valsts

Malta

Produkta apraksts

RSGD - Soft Starter, Three Phase

RSGD is an extremely compact and easy to use 3-phase soft starter for AC induction motors.
RSGD controls two phases and is internally bypassed to reduce the heat dissipation inside the panel.
Through its micro-controller based algorithm, the RSGD achieves an exceptional inrush current reduction resulting in smoother starting and stopping of motors. The starting parameters can be easily set-up through a 3- knob user interface and LED indications are provided for indication of supply, alarm and ramping/ bypass status.
RSGD provides a number of diagnostic functions including phase sequence, over- and under-voltage monitoring and locked rotor protection.

Carlo Gavazzi

Noliktavas stāvoklis patreiz nav pieejams

Lūdzu pārbaudiet vēlreiz vēlāk

Noliktavas stāvoklis patreiz nav pieejams

€ 424,93

Katrs (bez PVN)

€ 514,17

Katrs (Ieskaitot PVN)

Carlo Gavazzi Soft Starter, Soft Start, 5.5 kW, 400 V ac, 3 Phase, IP20

€ 424,93

Katrs (bez PVN)

€ 514,17

Katrs (Ieskaitot PVN)

Carlo Gavazzi Soft Starter, Soft Start, 5.5 kW, 400 V ac, 3 Phase, IP20
Noliktavas stāvoklis patreiz nav pieejams

Tehniskie dokumenti

Specifikācija

Power Rating

5.5 kW

Motor Starter Type

Soft Start

Voltage Rating

400 V ac

Phase

3

Current Rating

25 A

IP Rating

IP20

Overall Length

125mm

Overall Width

45mm

Overall Depth

109.8mm

Series

RSGD

Izcelsmes valsts

Malta

Produkta apraksts

RSGD - Soft Starter, Three Phase

RSGD is an extremely compact and easy to use 3-phase soft starter for AC induction motors.
RSGD controls two phases and is internally bypassed to reduce the heat dissipation inside the panel.
Through its micro-controller based algorithm, the RSGD achieves an exceptional inrush current reduction resulting in smoother starting and stopping of motors. The starting parameters can be easily set-up through a 3- knob user interface and LED indications are provided for indication of supply, alarm and ramping/ bypass status.
RSGD provides a number of diagnostic functions including phase sequence, over- and under-voltage monitoring and locked rotor protection.

Carlo Gavazzi