ABB Electronic Circuit Breaker 0.5A 24V EPD24, DIN Rail Mount

RS noliktavas nr.: 914-4590Ražotājs: ABBRažotāja kods: 2CDE601101R2905
brand-logo
Skatīt visu Elektroniskie jaudas slēdži

Tehniskie dokumenti

Specifikācija

Brand

ABB

Series

EPD24

Current Rating

0.5A

Rated DC Voltage

24V

Mounting Style

DIN Rail Mount

Izcelsmes valsts

Germany

Produkta apraksts

EPD24 Series Electronic Protection Device

ABB EPD24 series electronic protection devices offer overcurrent protection for 24 V dc load circuits. This protection is achieved by a combination of active electronic current limitations. In the case of a short circuit and an overload, deactivation from 1.1 x Input occurs.
If a fault occurs in a load circuit, the EPD24 protection device will detect this rapidly and reliably, disable the power output transistor, interrupting the current flow in the defective circuit. The maximum possible overcurrent is always limited to 1.3…1.8 times the selected rated current. An activation of capacitive loads up to 20,000 μF is possible, deactivation only occurring in the case of overloads or short circuits.

Noliktavas stāvoklis patreiz nav pieejams

Lūdzu pārbaudiet vēlreiz vēlāk

Noliktavas stāvoklis patreiz nav pieejams

€ 171,00

Katrs (bez PVN)

€ 206,91

Katrs (Ieskaitot PVN)

ABB Electronic Circuit Breaker 0.5A 24V EPD24, DIN Rail Mount

€ 171,00

Katrs (bez PVN)

€ 206,91

Katrs (Ieskaitot PVN)

ABB Electronic Circuit Breaker 0.5A 24V EPD24, DIN Rail Mount
Noliktavas stāvoklis patreiz nav pieejams

Pirkt iepakojumos

DaudzumsVienības cena
1 - 4€ 171,00
5 - 9€ 163,00
10 - 24€ 148,00
25 - 49€ 140,00
50+€ 132,00

Tehniskie dokumenti

Specifikācija

Brand

ABB

Series

EPD24

Current Rating

0.5A

Rated DC Voltage

24V

Mounting Style

DIN Rail Mount

Izcelsmes valsts

Germany

Produkta apraksts

EPD24 Series Electronic Protection Device

ABB EPD24 series electronic protection devices offer overcurrent protection for 24 V dc load circuits. This protection is achieved by a combination of active electronic current limitations. In the case of a short circuit and an overload, deactivation from 1.1 x Input occurs.
If a fault occurs in a load circuit, the EPD24 protection device will detect this rapidly and reliably, disable the power output transistor, interrupting the current flow in the defective circuit. The maximum possible overcurrent is always limited to 1.3…1.8 times the selected rated current. An activation of capacitive loads up to 20,000 μF is possible, deactivation only occurring in the case of overloads or short circuits.