Tehniskie dokumenti
Specifikācija
Brand
Phoenix ContactSuppressor Type
Surge Arrester Protection Module
Maximum Voltage Rating
230 V ac
Mounting Type
Through Hole
Maximum Surge Current
40kA
Series
F-MS 12 ST
Length
52.5mm
Depth
17.4mm
Height
55.5mm
Dimensions
52.5 x 17.4 x 55.5mm
Minimum Operating Temperature
-40°C
Maximum Operating Temperature
+80°C
Izcelsmes valsts
Germany
Produkta apraksts
Single & 3-phase Mains FLT & VAL Series
Pluggable modules on a fixed base element, for easy installation and fast replacement.
Standards
IEC 61643, VDE V 0185-3
Surge Protection Devices, SPDs (DIN-rail)
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.
Noliktavas stāvoklis patreiz nav pieejams
Lūdzu pārbaudiet vēlreiz vēlāk
€ 77,00
Katrs (bez PVN)
€ 93,17
Katrs (Ieskaitot PVN)
1
€ 77,00
Katrs (bez PVN)
€ 93,17
Katrs (Ieskaitot PVN)
1
Pirkt iepakojumos
Daudzums | Vienības cena |
---|---|
1 - 9 | € 77,00 |
10 - 24 | € 69,00 |
25 - 49 | € 62,50 |
50 - 99 | € 56,00 |
100+ | € 50,50 |
Tehniskie dokumenti
Specifikācija
Brand
Phoenix ContactSuppressor Type
Surge Arrester Protection Module
Maximum Voltage Rating
230 V ac
Mounting Type
Through Hole
Maximum Surge Current
40kA
Series
F-MS 12 ST
Length
52.5mm
Depth
17.4mm
Height
55.5mm
Dimensions
52.5 x 17.4 x 55.5mm
Minimum Operating Temperature
-40°C
Maximum Operating Temperature
+80°C
Izcelsmes valsts
Germany
Produkta apraksts
Single & 3-phase Mains FLT & VAL Series
Pluggable modules on a fixed base element, for easy installation and fast replacement.
Standards
IEC 61643, VDE V 0185-3
Surge Protection Devices, SPDs (DIN-rail)
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.