Tehniskie dokumenti
Specifikācija
Brand
RosemountDevice Type
Guided Wave Radar
Mounting Type
Top Mount
Body Material
Polyurethane-covered Aluminium
Cable Length
10m
Minimum Operating Temperature
-15°C
Maximum Operating Temperature
+150°C
Maximum dc Voltage
42.4V
Maximum Pressure
40bar
Series
5300
Standards Met
ATEX, CSA, EAC, EU, FM, IE, IEC, IM, NCC, SBS, SBV, SDN, SIL, SIS, SLL
Izcelsmes valsts
United Kingdom
Produkta apraksts
5301 Enhanced Guided Wave Radar
Emersons 5300 series of high performance guided wave transmitters are suitable for both level and interface measurement delivering accurate results with minimal maintenance and calibration requirements.
Utilising guided wave measurement technology the 5301 can be used in applications where both vapour and turbulence are present and does not require compensation for changes in temperature, density or pressure and can be installed in most level and liquid storage applications including those with small tanks, obstructions and difficult storage vessel geometry.
€ 4 761,14
€ 4 761,14 Katrs (bez PVN)
€ 5 760,98
€ 5 760,98 Katrs (Ieskaitot PVN)
1
€ 4 761,14
€ 4 761,14 Katrs (bez PVN)
€ 5 760,98
€ 5 760,98 Katrs (Ieskaitot PVN)
1
Noliktavas stāvoklis patreiz nav pieejams
Lūdzu pārbaudiet vēlreiz vēlāk
Tehniskie dokumenti
Specifikācija
Brand
RosemountDevice Type
Guided Wave Radar
Mounting Type
Top Mount
Body Material
Polyurethane-covered Aluminium
Cable Length
10m
Minimum Operating Temperature
-15°C
Maximum Operating Temperature
+150°C
Maximum dc Voltage
42.4V
Maximum Pressure
40bar
Series
5300
Standards Met
ATEX, CSA, EAC, EU, FM, IE, IEC, IM, NCC, SBS, SBV, SDN, SIL, SIS, SLL
Izcelsmes valsts
United Kingdom
Produkta apraksts
5301 Enhanced Guided Wave Radar
Emersons 5300 series of high performance guided wave transmitters are suitable for both level and interface measurement delivering accurate results with minimal maintenance and calibration requirements.
Utilising guided wave measurement technology the 5301 can be used in applications where both vapour and turbulence are present and does not require compensation for changes in temperature, density or pressure and can be installed in most level and liquid storage applications including those with small tanks, obstructions and difficult storage vessel geometry.