PAT testeri
PAT testers, or portable appliance testers, are specialised testing devices that are essential for checking electrical devices for faults in a wide range of working environments. PAT testing equipment will provide a pass or fail for the appliance you are testing immediately, so you know it's safe to use. By using the appropriate type of PAT tester, you can identify potential electrical risks, miti...
Attēlo 1-20 no 130 produktiem
Fluke
PAT Tester Kit
Continuity, Current, Earth, Insulation, RCD, Voltage
Automatic, Manual
Yes
-
No
6500-2 UK
-
-
-
-
200 x 275 x 114mm
3.1kg
200mm
275mm
-
230V
-
-
114mm
6500-2 UK
Martindale
Pass/Fail PAT
Class I, Class II
Automatic
-
-
-
HPAT400/2
-
Battery
AA
600 (Test)
-
700g
210mm
90mm
+40°C
-
-
-10°C
54mm
HPAT400/2
Martindale
PAT Tester
Class I, Class II
Automatic, Manual
-
-
-
-
-
Battery
AA
600 (Test)
-
700g
210mm
90mm
+40°C
1.2V
-
-10°C
54mm
HPAT600/2
Chauvin Arnoux
Machine and Electrical Switchboard Testers
-
Automatic, Manual
Yes
-
Yes
CA 6161
Type F - Schuko plug
Mains
No battery
Mains powered
340 x 405 x 194mm
9kg
194mm
340mm
+45°C
3000V
40V
0°C
405mm
CA 6161
Chauvin Arnoux
Machine and Electrical Switchboard Testers
-
Automatic, Manual
Yes
-
Yes
CA 6163
Type F - Schuko plug
Mains
No battery
Mains powered
340 x 405 x 194mm
15kg
194mm
340mm
+45°C
5350V
40V
0°C
405mm
CA 6163
Gossen Metrawatt
PAT Tester
AC and DC Patient Leakage Current, Contact Current, Differential Current Measurement, Direct Measurement, Earth Leakage Current, Equivalent Leakage Current Procedure, Insulation Resistance, Patient Auxiliary Current, Protective Conductor Resistance
Automatic, Manual
-
-
No
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Gossen Metrawatt
PAT Tester
AC and DC Patient Leakage Current, Contact Current, Differential Current Measurement, Direct Measurement, Earth Leakage Current, Equivalent Leakage Current Procedure, Insulation Resistance, Patient Auxiliary Current, Protective Conductor Resistance
Automatic, Manual
-
-
No
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Gossen Metrawatt
Advanced PAT
AC and DC Patient Leakage Current, Class I, Class II, Class IT, Contact Current, Continuity, Current, Differential Current Measurement, Direct Measurement, Earth, Earth Leakage Current, Equivalent Leakage Current Procedure, Insulation, Insulation Resistance, Protective Conductor Resistance, RCD, Voltage
Automatic, Manual
Yes
DAkkS
Yes
-
-
Mains
-
-
295 x 145 x 150mm
2.5kg
145mm
295mm
+40°C
230V
-
-
-
SECUTEST LEMONGREEN
Martindale
PAT Tester
Class I, Class II
Automatic
-
-
-
HPAT500/2
-
Battery
AA
600 (Test)
-
700g
210mm
90mm
+40°C
1.2V
-
-10°C
54mm
HPAT500/2
Martindale
-
Class I, Class II
Automatic, Manual
-
RSCAL
-
-
-
Battery
AA
600 (Test)
-
700g
210mm
90mm
+40°C
1.2V
-
-10°C
54mm
HPAT600/2
Martindale
-
Class I, Class II
Automatic, Manual
-
UKAS
-
-
-
Battery
AA
600 (Test)
-
700g
210mm
90mm
+40°C
1.2V
-
-10°C
54mm
HPAT600/2
...