RS PRO 7W Lighting Controller Switch, Daylight, Surface Mount, 220 V
Tehniskie dokumenti
Specifikācija
Brand
RS ProController Type
Switch
Sensor Type
Daylight
Voltage Rating
220 V
Mount Type
Surface
Range
15 → 20 m, Adjustable
Power Consumption
7W
Time Delay
30 s
Length
90.8 mm
Current Rating
10 A
Series
565 07 S
Izcelsmes valsts
Germany
Produkta apraksts
Daylight Lighting Controllers
These controllers automatically turn lights 'ON' and 'OFF' in response to changes in ambient light levels, primarily the transition from day to night and vice-versa. The more advanced types (see note below) have inbuilt logic to minimise false triggering, whereas the remainder have inbuilt time delays or higher 'OFF' thresholds, to prevent on/off cycling. As a general rule, these controllers should be sited such that they are not illuminated, by the light they are controlling. Nominal supply voltage is 230Vac.,Note regarding energy-saving negative-hysteresis controllers,Where figures for the 'OFF' threshold are lower than for the 'ON' threshold, the sensor is designed such that four thresholds are actually monitored. These are: dusk, the middle of the night, dawn and the middle of the day. Monitoring at times other than dusk and dawn enables the sensor to determine what it should be looking for next, minimising false triggering and improving overall controller operation.
Noliktavas stāvoklis patreiz nav pieejams
Lūdzu pārbaudiet vēlreiz vēlāk
€ 77,00
Katrs (bez PVN)
€ 93,17
Katrs (Ieskaitot PVN)
1
€ 77,00
Katrs (bez PVN)
€ 93,17
Katrs (Ieskaitot PVN)
1
Pirkt iepakojumos
Daudzums | Vienības cena |
---|---|
1 - 11 | € 77,00 |
12 - 24 | € 73,00 |
25+ | € 71,00 |
Tehniskie dokumenti
Specifikācija
Brand
RS ProController Type
Switch
Sensor Type
Daylight
Voltage Rating
220 V
Mount Type
Surface
Range
15 → 20 m, Adjustable
Power Consumption
7W
Time Delay
30 s
Length
90.8 mm
Current Rating
10 A
Series
565 07 S
Izcelsmes valsts
Germany
Produkta apraksts
Daylight Lighting Controllers
These controllers automatically turn lights 'ON' and 'OFF' in response to changes in ambient light levels, primarily the transition from day to night and vice-versa. The more advanced types (see note below) have inbuilt logic to minimise false triggering, whereas the remainder have inbuilt time delays or higher 'OFF' thresholds, to prevent on/off cycling. As a general rule, these controllers should be sited such that they are not illuminated, by the light they are controlling. Nominal supply voltage is 230Vac.,Note regarding energy-saving negative-hysteresis controllers,Where figures for the 'OFF' threshold are lower than for the 'ON' threshold, the sensor is designed such that four thresholds are actually monitored. These are: dusk, the middle of the night, dawn and the middle of the day. Monitoring at times other than dusk and dawn enables the sensor to determine what it should be looking for next, minimising false triggering and improving overall controller operation.