Megger LTW325-EU-BS Loop Impedance & RCD Combined Tester, Loop Impedance Test Type 2 Wire 440V, RCD Test Type AC

RS noliktavas nr.: 238-139Ražotājs: MeggerRažotāja kods: LTW325-EU-BS
brand-logo
Skatīt visu Loop & RCD Testers

Tehniskie dokumenti

Specifikācija

Brand

Megger

Loop Impedance Test Type

2 Wire

Test Equipment Type

Combined Loop & RCD Tester

Calibrated

UKAS

Maximum Voltage Measurement

440V

RCD Test Type

AC Selective

Best Loop Test Accuracy

±10%

RCD Test Current

4A

Non-Trip Loop Test

Yes

Safety Category

CAT IV 300 V, IEC 61010

Display Type

LCD

Battery Life

2000 tests

Battery Type

AA

Power Source

Battery

Weight

1000g

Safety Category Level

CAT IV

Safety Category Voltage

300V

Maximum Operating Temperature

+50°C

Width

148mm

Length

203mm

Minimum Operating Temperature

-10°C

Height

78mm

Model Number p

LTW325

Izcelsmes valsts

United Kingdom

Produkta apraksts

LTW 300 Series

Earth loop impedance testers to verify the loop impedance of a live electrical circuit without the need to disconnect the electrical supply. The LTW300 series instruments offer a safe and easy 2 wire loop testing solution that does not trip 30mA RCDs and can be used on a wide range of voltages.

Supplied with

Test lead set with crocodile clips, mains socket test lead, 8 AA alkaline batteries, hard carry case and instructions.

Noliktavas stāvoklis patreiz nav pieejams

Lūdzu pārbaudiet vēlreiz vēlāk

Noliktavas stāvoklis patreiz nav pieejams

€ 1 125,00

Katrs (bez PVN)

€ 1 361,25

Katrs (Ieskaitot PVN)

Megger LTW325-EU-BS Loop Impedance & RCD Combined Tester, Loop Impedance Test Type 2 Wire 440V, RCD Test Type AC

Kalibrācijas veids

€ 1 125,00

Katrs (bez PVN)

€ 1 361,25

Katrs (Ieskaitot PVN)

Megger LTW325-EU-BS Loop Impedance & RCD Combined Tester, Loop Impedance Test Type 2 Wire 440V, RCD Test Type AC
Noliktavas stāvoklis patreiz nav pieejams

Kalibrācijas veids

Tehniskie dokumenti

Specifikācija

Brand

Megger

Loop Impedance Test Type

2 Wire

Test Equipment Type

Combined Loop & RCD Tester

Calibrated

UKAS

Maximum Voltage Measurement

440V

RCD Test Type

AC Selective

Best Loop Test Accuracy

±10%

RCD Test Current

4A

Non-Trip Loop Test

Yes

Safety Category

CAT IV 300 V, IEC 61010

Display Type

LCD

Battery Life

2000 tests

Battery Type

AA

Power Source

Battery

Weight

1000g

Safety Category Level

CAT IV

Safety Category Voltage

300V

Maximum Operating Temperature

+50°C

Width

148mm

Length

203mm

Minimum Operating Temperature

-10°C

Height

78mm

Model Number p

LTW325

Izcelsmes valsts

United Kingdom

Produkta apraksts

LTW 300 Series

Earth loop impedance testers to verify the loop impedance of a live electrical circuit without the need to disconnect the electrical supply. The LTW300 series instruments offer a safe and easy 2 wire loop testing solution that does not trip 30mA RCDs and can be used on a wide range of voltages.

Supplied with

Test lead set with crocodile clips, mains socket test lead, 8 AA alkaline batteries, hard carry case and instructions.