Fluke 1664FC Multifunction Tester, 50V , Earth Resistance Measurement With BLE, USB RS Calibration

RS noliktavas nr.: 113-5140Ražotājs: FlukeRažotāja kods: FLK-1664FC UK
brand-logo
View all in Multifunction Testers

Tehniskie dokumenti

Specifikācija

Brand

Fluke

Loop Impedance Test Type

Phase to Earth, Phase to Neutral

Calibrated

RSCAL

Automatic RCD Test

Yes

RCD Ramp Test

Yes

Model Number p

1664FC

Insulation Test Voltage

50 V, 100 V, 250 V, 500 V, 1000V

Maximum Voltage Measurement

500V ac/dc

Test Type

Continuity, Frequency, Insulation Resistance, Loop and Line Resistance, Measure Motor Windings, Phase Sequence Test, Prospective Earth Fault Current, Prospective Short Circuit Current, RCD Test, Resistance, Voltage, Wiring Polarity

Earth Resistance Measurement

Yes

Downloadable Data

Yes

Interface Type

BLE, USB

Continuity Test Current

10mA

RCD Test Type

A, AC, B5, S

Remote Switch Mode

Yes

Test Standards

IEC 60364

IP Rating

IP40

Power Source

Battery

Width

250mm

Length

100mm

Weight

1.3 (with Battery)kg

Safety Category Level

CAT III, CAT IV

Plug Type

UK

Maximum Continuity Resistance

2000Ω

Safety Category Voltage

300 V, 500 V

Voltage Measurement Range

50 → 1000V

Battery Type

AA

Safety Category

CAT III 500 V, CAT IV 300 V

Dimensions

100 x 250 x 125mm

Minimum Continuity Resistance

20Ω

Height

125mm

Izcelsmes valsts

United Kingdom

Noliktavas stāvoklis patreiz nav pieejams

Lūdzu pārbaudiet vēlreiz vēlāk

Noliktavas stāvoklis patreiz nav pieejams

€ 2 980,00

Katrs (bez PVN)

€ 3 605,80

Katrs (Ieskaitot PVN)

Fluke 1664FC Multifunction Tester, 50V , Earth Resistance Measurement With BLE, USB RS Calibration

€ 2 980,00

Katrs (bez PVN)

€ 3 605,80

Katrs (Ieskaitot PVN)

Fluke 1664FC Multifunction Tester, 50V , Earth Resistance Measurement With BLE, USB RS Calibration
Noliktavas stāvoklis patreiz nav pieejams

Tehniskie dokumenti

Specifikācija

Brand

Fluke

Loop Impedance Test Type

Phase to Earth, Phase to Neutral

Calibrated

RSCAL

Automatic RCD Test

Yes

RCD Ramp Test

Yes

Model Number p

1664FC

Insulation Test Voltage

50 V, 100 V, 250 V, 500 V, 1000V

Maximum Voltage Measurement

500V ac/dc

Test Type

Continuity, Frequency, Insulation Resistance, Loop and Line Resistance, Measure Motor Windings, Phase Sequence Test, Prospective Earth Fault Current, Prospective Short Circuit Current, RCD Test, Resistance, Voltage, Wiring Polarity

Earth Resistance Measurement

Yes

Downloadable Data

Yes

Interface Type

BLE, USB

Continuity Test Current

10mA

RCD Test Type

A, AC, B5, S

Remote Switch Mode

Yes

Test Standards

IEC 60364

IP Rating

IP40

Power Source

Battery

Width

250mm

Length

100mm

Weight

1.3 (with Battery)kg

Safety Category Level

CAT III, CAT IV

Plug Type

UK

Maximum Continuity Resistance

2000Ω

Safety Category Voltage

300 V, 500 V

Voltage Measurement Range

50 → 1000V

Battery Type

AA

Safety Category

CAT III 500 V, CAT IV 300 V

Dimensions

100 x 250 x 125mm

Minimum Continuity Resistance

20Ω

Height

125mm

Izcelsmes valsts

United Kingdom